SUP-LUGB Vortex flowmeter work on the principle of generated vortex and relation between vortex and flow by theory of Karman and Strouhal, which specialize in measurement of steam, gas and liquid of lower viscosity.
Pipe diameter: DN10-DN500
Accuracy: 1.0% 1.5%
Range Ratio: 1:8
Ingress protection: IP65
Product |
Vortex flowmeter with temperature & pressure compensation |
Model |
SUP-LUGB |
Diameter nominal |
DN10~DN500 |
Installation |
Wafer connection: DN10-DN500(priority PN2.5MPa) Flange connection: DN10-DN80(priority PN2.5MPa);DN100-DN200(priority PN1.6MPa);DN250-DN500(priority PN1.0MPa) |
Accuracy |
1.5%, 1.0% |
Range Ratio |
8:1 |
Medium Temperature |
-20°C ~ +150°C, -20°C ~ +260°C, -20°C ~ +320°C, -20°C ~ +420°C |
Output signal |
4-20mA |
Frequency |
RS485 communication (Modbus RTU) |
Power supply |
24VDC±5% Li battery(3.6VDC) |
Ingress protection |
IP65 |
Body Materials |
Stainless shell |
Display |
128*64 dot matrix LCD |